CVE-2018-14558
Tenda AC7, AC9, and AC10 Routers Command Injection Vulnerability
Tenda AC7, AC9, and AC10 Routers
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input.
Exploitation status
CISA Known Exploited Vulnerabilities
Listed by CISA on 3 November 2021. US federal agencies were required to remediate it by 3 May 2022.
EPSS — exploitation probability
FIRST puts the probability of exploitation activity in the next 30 days at 8.5%, which is higher than 95.2% of all scored vulnerabilities. EPSS is a forecast of activity, not a measure of severity, and it is rescored daily.
CVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Frequently asked questions
Is CVE-2018-14558 being exploited by ransomware groups?
No ransomware group in this database is currently recorded as exploiting CVE-2018-14558.
What does CVE-2018-14558 affect?
CVE-2018-14558 affects Tenda AC7, AC9, and AC10 Routers. An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input.
How severe is CVE-2018-14558?
CVE-2018-14558 is rated CRITICAL with a CVSS base score of 9.8. EPSS puts the probability of exploitation in the next 30 days at 8.5%, higher than 95.2% of all scored vulnerabilities. It is listed in the CISA Known Exploited Vulnerabilities catalog, with a federal remediation deadline of 3 May 2022.
How should organisations respond to CVE-2018-14558?
Apply the vendor patch for Tenda AC7, AC9, and AC10 Routers as the first priority, and treat any internet-facing instance as the most urgent. Because this vulnerability is associated with ransomware activity, also review whether the affected systems were reachable before patching, rather than assuming that patching alone closes the incident.